Medical Resarch Library
This page contains a number of medical research studies pertaining to metal debris wear of metal-on-metal hip implants, cobalt & chromium toxicity, metal hypersensitivity, and other issues surrounding the DePuy ASR hip implant recall.
If you have questions or would like to discuss your case with a medical device recall lawyer, fill out the contact form on this page, or call 888-290-4472 for a free & confidential case evaluation.
- Blood Metal Ion Testing is an Effective Screening Tool to Identify Poorly Performing Metal-on-Metal Bearing Surfaces
- FDA Executive Summary Memorandum for Metal-on-Metal Hip Implant Systems Prepared for the June 27-28, 2012 Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel
- Appendix I: Summary of Medical Device Adverse Event Reports (for FDA Executive Meeting June 27-28, 2012)
- Medical Device Alert: All metal-on-metal (MOM) hip replacements, February 28, 2012
- Cobalt Toxicity: An emerging clinical problem in patients with metal-on-metal hip prostheses? Medical Journal of Australia, May 26, 2011
- Arthroprosthetic Cobaltism: Neurological and Cardiac Manifestations in Two Patients with Metal-on-Metal Arthroplasty: A Case Report Journal of Bone & Joint Surgery, October 29, 2010
- Metal Release in Patients Who Have Had a Primary Total HIp Arthroplasty, The Journal of Bone & Joint Surgery, September 27, 2010
- Metal-on-Metal Bearings in Primary Total Hip Arthroplasty: Minimum 2-year Follow Up, Joint Implant Surgeons, Inc., March 9-13, 2010
- Metal Hypersensitivity Testing in Total Joint Arthroplasty Patients, Joint Implant Surgeons, Inc. March 9-13, 2010
Metal-on-Metal Bearing Surfaces Perspectives on Modern Orthopaedics, February 2009 - Loosening and Osteolysis Associated with Metal-on-Metal Bearings: a Local Effect of MetalHypersensitivity? The Journal of Bone & Joint Surgery, September 4, 2010
- Modern Metal-on-Metal Hip Resurfacing, Journal of the American Academy of Orthopaedic Surgeons, May 2010
- The Validity of Serum Levels as a Surrogate Measure of Systemic Exposure to Metal Ions in Hip Replacement, Journal of Bone & Joint Surgery, 2007
- Metallosis due to impingement between the socket and the femoral head in a total hip prosthesis. A case report. 2002, Journal of Bone & Joint Surgery
- Cobalt-Chromium-Molybdenum Alloy Causes Metal Accumulation and Metallothionein Up-Regulation in Rat Liver and Kidney, Department of Neurobiology, Institute of Anatomy, University of Aarhus, Aarhus, Denmark
- Metal Ion Toxicity References 1996 – 2002
- Carcinogenicity of Hexavalent Chromium, Wise Laboratory of Environmental & Genetic Toxicology, Maine Center for Toxicology, October 2008
- Complications Associated with Hip Resurfacing Arthroplasty, Orthopedic Clinics of North America, 2005
- DePuy ASR Hip Prosthesis Index to Research Materials
- Early Failure of Metal-on-Metal Bearings in Hip Resurfacing and Large-Diameter Total Hip Replacement: A Consequence of Excess Wear, The Journal of Bone & Joint Surgery, January 2010
- The Effects of Component Size and Orientation on the Concentrations of Metal Ions After Resurfacing Arthroplasty of the Hip, The Journal of Bone & Joint Surgery, September 2008
- Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing, The Journal of Bone & Joint Surgery, September 4, 2010
- Loosening and Osteolysis Associated with Metal-on-Metal Bearings: A Local Effect of Metal Hypersensitivity? The Journal of Bone & Joint Surgery, September 4, 2010
- Complications Associated with Hip Resurfacing Arthroplasty, Orthopedic Clinics of North America, 2005
- Articular Surface Replacement of the Hip: A Prospective Single-Surgeon Series, The Journal of Bone & Joint Surgery, 2010
- Elevated Levels of Cobalt and Chromium Found in Offspring of Moms with Metal-on-Metal Hip Implants Rush University Medical Center, March 9, 2010
- World Health Organization International Agency for Research on Cancer (IARC) Monographs on the Evaluation of Carcingenic Risks to Humans Volume 86: Cobalt in Hard Metals and Cobalt Sulfate, Gallium Arsenide, Indium Phosphide and Vanadium Pentoxide, 2006
- Cellular and Molecular Pathways Linking Inflammation and Cancer, University of Piemonte Orientale A. Avogadro, Novara, Italy, July 17, 2009
- Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements, March 2003, Journal of Orthopaedic Research
- Metallosis due to impingement between the socket and the femoral head in a total hip prosthesis. A case report. 2002, Journal of Bone Joint Surgery
Time to get help!
Do you have an advocate looking out for your best interest? At Kershaw, Cutter & Ratinoff, we represent hundreds of hip replacement patients who, for decades, continue to rely on our knowledge and expertise in fighting and winning cases in the mass tort and medical device arenas. All it takes is 3 simple steps! Start by sharing your story with us through our free evaluation form on this page or we invite you to give us a call toll free at 888-290-4472 for a no-cost, confidential case review.
At Kershaw, Cutter & Ratinoff, we look forward to serving you and your family.